Solar energy paper index
Frequency Control Capability Estimation for Renewable Energy Stations Accounting for Dynamic Response Variations and Power Decoupling
One-line summary
A solar energy research paper on Frequency Control Capability Estimation for Renewable Energy Stations Accounting for Dynamic Response Variations and Power Decoupling.
Engineering notes
Engineering notes will be added by the Power for Solar editorial team.
Chinese explanation / 中文解读
中文解读待补充:本站会优先为光伏效率、钙钛矿太阳能电池、储能技术、太阳能热利用、BIPV、并网技术等高价值论文补充中文说明。
Original abstract
The large-scale integration of converter-interfaced renewable energy sources has significantly reduced power system inertia, posing challenges to frequency stability. Although virtual inertia and primary frequency control can enhance the frequency support capability of renewable energy units, their actual performance often deviates from set values due to dynamic response differences among various energy sources (e.g., energy storage, photovoltaic, and wind power) and coupling between inertia and primary regulation power. Existing evaluation methods fail to accurately decouple these components or account for unit-specific dynamic characteristics, leading to considerable estimation errors. To address these issues, this paper proposes a novel estimation method for the frequency regulation capability of renewable energy stations. First, the dynamic frequency response characteristics of synchronous and renewable generators are compared. Then, a decoupling method is developed to separate virtual inertia power from primary frequency regulation power by leveraging their distinct response features. A first-order plus delay time (FOPDT) model is employed to characterize the external frequency response of different renewable energy units. The primary frequency regulation coefficient is estimated using a sliding window integration method, and the virtual inertia time constant is identified via a gradient descent algorithm based on the decoupled inertia power. A hardware-in-the-loop experimental platform is constructed using a real-time digital simulator (RTDS) and phasor measurement units (PMUs) to validate the proposed method. Simulation results show that the estimation errors for energy storage, photovoltaic, and wind power units are 0.63%, 6.38%, and 8.38% for the virtual inertia time constant and 0.45%, 0.72%, and 3.81% for the primary frequency regulation coefficient, respectively. Field test data further confirm the practical applicability and accuracy of the approach. The proposed method enables precise frequency control capability estimation, providing a reliable basis for parameter setting and capacity configuration of frequency regulation resources in low-inertia power systems.
Links and sources
Need this topic turned into a technical roadmap?
Power for Solar can prepare a custom solar energy literature review, simulation code map, dataset map, and B2B photovoltaic technology assessment.
Request B2B research
Comments