Solar energy paper index

From Building Services to Process Loads: Whole-Building Utility-Calibrated Simulation of Sustainable Operational Decarbonisation Limits in a UK SME Restaurant Retrofit

2026-06-26 · Sustainability

One-line summary

A solar energy research paper on From Building Services to Process Loads: Whole-Building Utility-Calibrated Simulation of Sustainable Operational Decarbonisation Limits in a UK SME Restaurant Retrofit.

Engineering notes

Engineering notes will be added by the Power for Solar editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为光伏效率、钙钛矿太阳能电池、储能技术、太阳能热利用、BIPV、并网技术等高价值论文补充中文说明。

Original abstract

Restaurants combine long opening hours, catering demand, kitchen ventilation, DHW, and mixed-fuel cooking loads, making their decarbonisation different from generic commercial retrofit. For small- and medium-sized enterprise (SME) hospitality premises, this makes the transition to net-zero operation a distinct sustainability challenge because a large, process-driven share of demand lies outside conventional building-fabric and building-services retrofit. This single-case study develops a whole-building utility-calibrated OpenStudio/EnergyPlus model for Beit El Zaytoun, a 655.82 m2 restaurant in Park Royal, London. Monthly electricity and gas data for June 2024–May 2025 were used to calibrate the baseline at whole-building level. Standalone and cumulative scenarios tested insulation, low-emissivity double glazing, LED lighting and controls, ASHP service scenarios, and an 11 kWp PV array. Baseline demand was 413,895 kWh/yr, equivalent to 631.1 kWh/m2·yr and 75,020 kgCO2e/yr. The lowest-net-energy analytical package reduced net imported energy to 314,734 kWh/yr and operational carbon to 56,700 kgCO2e/yr, a retained 24.0% reduction on the source reporting basis; this package is treated as an analytical bound rather than as a final design recommendation because it excludes cooling. The model-derived residual process load, kitchen and catering gas plus kitchen, and back-of-house electricity remained 233,920 kWh/yr across building-focused scenarios. The Residual-Load Index (RLI) rose from 0.57 to 0.74; with ±15% process-load allocation uncertainty, the optimised RLI range was 0.63–0.85, so the post-retrofit balance remained process-load dominated. The case demonstrates a practical decarbonisation ceiling likely to recur in similar high-process-load hospitality premises: fabric, lighting, heat electrification, and PV are necessary but insufficient without catering-equipment, cooking-fuel, kitchen-ventilation, refrigeration-control, sub-metering, and demand-response strategies. The paper contributes whole-building utility-calibrated quantitative evidence and a transferable RLI metric for sub-sector-specific sustainable retrofit policy, and the net-zero transition of SME food-service premises.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Need this topic turned into a technical roadmap?

Power for Solar can prepare a custom solar energy literature review, simulation code map, dataset map, and B2B photovoltaic technology assessment.

Request B2B research

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment