Solar energy paper index

Impedance MPC with Patient-Torque Estimation for Knee Rehabilitation Exoskeletons

2026-06-11 · arXiv: 2606.13485

One-line summary

A solar energy research paper on Impedance MPC with Patient-Torque Estimation for Knee Rehabilitation Exoskeletons.

Engineering notes

Engineering notes will be added by the Power for Solar editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为光伏效率、钙钛矿太阳能电池、储能技术、太阳能热利用、BIPV、并网技术等高价值论文补充中文说明。

Original abstract

Knee rehabilitation exoskeletons must enforce a prescribed joint trajectory while remaining safely compliant with involuntary spasm and voluntary patient effort-objectives in tension for any fixed-gain impedance controller. We present an Impedance Model Predictive Control framework for knee rehabilitation exoskeletons, demonstrated on a series-elastic-actuator (SEA) platform: an algebraic feedforward reduces the knee dynamics to a constant-coefficient scalar double integrator, and a receding-horizon quadratic program (QP) computes corrective torques while enforcing hard range-of-motion, torque, and velocity limits (ISO 13482). A Kalman disturbance state driven by direct SEA-based torque sensing (the series-elastic spring deflection measured through the elastic element - an intrinsic, EMG-free patient-torque estimate, not a separate load cell) gives a nominal offset-free guarantee and, via its sign and the desired-motion direction, sensorless Assist-as-Needed. The constant state matrix permits offline precomputation of the QP cost inverse, enabling 500 Hz operation with a multi-step horizon. Across seven-controller benchmarks (sinusoidal tracking, isometric hold), the 500 Hz Kalman MPC is offset free 0.1 mrad RMS, 0.1 mrad steady-state, 0.2 mrad peak under 15 Nm spasm, versus a 515 mrad steady-state offset for classical impedance at the same stiffness - the direct-measurement channel converging the estimate near-immediately (within a few sampling periods). Without the estimator it realizes a classical impedance (4.8 mrad RMS, 8.3 mrad steady-state). All MPC variants meet the 87 mrad clinical criterion; no classical controller does. The architecture is formulated for the 20 DOF MyoSuite myoLeg via coupling-aware per-joint QPs.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Need this topic turned into a technical roadmap?

Power for Solar can prepare a custom solar energy literature review, simulation code map, dataset map, and B2B photovoltaic technology assessment.

Request B2B research

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment