Solar energy paper index

Research on a fast self-healing control method for tie-line faults in regional distribution networks based on source–load–storage interaction

2026-06-02 · Scientific Reports

One-line summary

A solar energy research paper on Research on a fast self-healing control method for tie-line faults in regional distribution networks based on source–load–storage interaction.

Engineering notes

Engineering notes will be added by the Power for Solar editorial team.

Chinese explanation / 中文解读

中文解读待补充:本站会优先为光伏效率、钙钛矿太阳能电池、储能技术、太阳能热利用、BIPV、并网技术等高价值论文补充中文说明。

Original abstract

To address the challenges of islanding susceptibility, complex network topology, and insufficient coordination between traditional protection and stability control under high penetration of distributed generation in regional distribution networks, a fast fault self-healing control method based on source-load-storage coordinated interaction is proposed. The frequency and voltage dynamic characteristics of regional distribution networks after disconnection from the main grid are systematically analyzed, revealing the relationship between tie-section power exchange and island stability. A full-process fast self-healing framework is established, covering fault isolation, island detection, stable control, and grid reconnection, along with a master-slave self-healing architecture enabling multi-level information sharing and coordinated decision-making. To cope with the difficulty of accurate island identification caused by variable topology, an island detection method based on a pruning-optimized search strategy is developed, improving real-time performance by eliminating unnecessary low-voltage branches. A circuit breaker position fault-tolerant mechanism based on enumeration and current criteria enhances robustness against switch status anomalies. For island stability control, a "regulation-priority with regulation-shedding coordination" principle is adopted, prioritizing rapid regulation of distributed resources such as energy storage and photovoltaics. Simulation and field tests show that the proposed method reduces recovery time by over 50% (from 6.8 s to 3.2 s), limits frequency deviation to 0.15 Hz, and decreases load loss to 12%, compared with conventional load shedding strategies. These results verify the method's effectiveness, robustness, and practical applicability for real-time full-process dynamic self-healing in regional distribution networks.

5.0Engineering value
7.0Research novelty
4.0Business relevance

Links and sources

Need this topic turned into a technical roadmap?

Power for Solar can prepare a custom solar energy literature review, simulation code map, dataset map, and B2B photovoltaic technology assessment.

Request B2B research

Comments

No comments yet. Be the first to share your thoughts on this paper.
Login or register to leave a comment